User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 8
Color Stability Assessment of Three Different Resin Composites After Polymerization with Two Different Light-Curing Units
2023
Journal:  
European Annals of Dental Sciences
Author:  
Abstract:

Purpose: Despite improvements in resin composite structures, color stability remains a challenge, and esthetic problems are the most common factors in renewing restorations. This study aimed to evaluate the effects of two light-curing units on the color stability of three different resin composite materials during a six-month period. Materials & Methods: Three different resin composites (Filtek Z550, Filtek Ultimate Flowable, Filtek Bulk Fill Restorative) with an A2 color shade were prepared for each combination of resin composite-curing unit (5x2mm) for a total of 30 specimens. Specimens were cured with either QTH Hilux Ultraplus (700mW/cm2) for 40 seconds or Radii Plus LED Curing Light (1400mW/cm2) for 20 seconds. For standardization of the amount of transmitted energy to the composite, all specimens received 28J/cm2. Color parameters were measured with a colorimeter (Minolta CR-321, Konica Minolta Sensing Pte Ltd, Singapore) after polymerization and at 24 hours, first week, first month, third month, and sixth month. Color changes(∆E) were calculated for the different storage periods. One-factor repeated three-way analysis of variance (ANOVA) was used to examine the changes in ΔE measurements over time for different fillers and devices. Results: Significant differences between composites and periods were observed in the color stability with polymerization either QTH or LED. Independently of the composites, there was no significant difference at the end of six months between QTH and LED units with a fixed energy density. The Filtek Z550 material showed the smallest and the Filtek Ultimate Flowable material showed the highest ∆E values at the end of the six months among the materials used. Conclusion: Clinically acceptable color changes were observed for all the materials at the end of six months.

Keywords:

0
2023
Author:  
Citation Owners
Information: There is no ciation to this publication.
Similar Articles












European Annals of Dental Sciences

Field :   Sağlık Bilimleri

Journal Type :   Ulusal

Metrics
Article : 428
Cite : 189
2023 Impact : 0.013
European Annals of Dental Sciences