User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
  Citation Number 1
 Views 11
 Downloands 1
The effect of inter-implant distance on retention and resistance to dislodging forces for mandibular implant-tissue-supported overdentures.
2014
Journal:  
Frontiers in Dentistry
Author:  
Abstract:

The effect of inter-implant distance on retention and resistance of implant-tissue-supported overdentures is lacking in the literature. An in vitro study was performed to evaluate this effect for mandibular implant-tissue-supported overdentures retained by two ball attachments.An acrylic cast of an edentulous mandible was fabricated. Three pairs of implants were symmetrically placed at both sides of the midline. The inter-implant distance was 10, 25, and 35 millimeters in positions A, B and C, respectively. A framework simulating the overdenture was fabricated on the cast. Six attachment housings were placed within the overdenture. For each sample, two ball abutments were screwed onto the implant pairs and two pink nylon inserts were seated in their respective attachment housings. The samples were tested in three groups of 15 (A, B, and C). The testing machine applied tensile dislodging forces and peak loads were measured in three directions: vertical, oblique, and anterior-posterior. A one-way ANOVA followed by Tukey's HSD was used to determine groups that were significantly different. Tests were carried out at 0.05 level of significance.Peak loads for the anterior-posteriorly directed dislodging forces were significantly the highest for group C (P<0.05); 21.25 N±3.05 N, while there were no statistically significant differences among groups with vertically and obliquely directed forces (P>0.05).Inter-implant distance did not affect the vertical retention and oblique resistance of mandibular implant-tissue-supported overdentures; however, it affected anterior-posterior resistance.

Keywords:

Citation Owners
Attention!
To view citations of publications, you must access Sobiad from a Member University Network. You can contact the Library and Documentation Department for our institution to become a member of Sobiad.
Off-Campus Access
If you are affiliated with a Sobiad Subscriber organization, you can use Login Panel for external access. You can easily sign up and log in with your corporate e-mail address.
Similar Articles












Frontiers in Dentistry

Field :   Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 854
Cite : 371
Frontiers in Dentistry