Mikro Şebekelerde Güç Kalitesinin İyileştirilmesi için D-STATCOM Tasarımı ve Analizi
2021
Journal:  
Politeknik Dergisi
Author:  
Abstract:

Endüstriyel uygulamalarda kullanılan yüklerin büyük bir kısmı gelişen teknolojiyle birlikte endüktif yüklerden oluşmaktadır. Endüktif yükler, yapıları gereği endüktif reaktif enerji tüketmektedirler. Tüketilen bu reaktif enerji, sistemin kalitesinde ve verimliliğinde düşüşe ve güç faktöründe sorunlara neden olmaktadır. Esnek alternatif akım iletim sistemleri (FACTS), güç sisteminin performansını ve kalitesini arttırmada önemli bir rol oynamaktadır. FACTS sistemiyle donatılmış bir güç sisteminin kontrolü daha hızlı ve kolaydır. Dağıtım Statik Senkron Kompanzatör (D-STATCOM), güç kalitesini arttırmak için kullanılan en yaygın FACTS cihazıdır. Reaktif güç kontrolü için kullanılan D-STATCOM, dağıtım sistemlerinde güç kalitesini arttırmak amacıyla kullanılan şönt bir cihazdır. D-STATCOM şebeke ile reaktif güç alış verişinde bulunarak gerilim dalgalanmalarını önler. Bu çalışmada, güç kalitesi problemlerinin kaynağında yok edilebilmesi için dağıtım hattıyla reaktif güç alışverişi yapan ve gerilim kaynaklı dönüştürücü temeline dayanan D-STATCOM’un modellenmesi MATLAB Simulink kullanılarak yapılmış ve benzetim sonuçları incelenmiştir. Modellenen sistemde, 4 km uzunluğunda bir dağıtım hattı, hat sonunda kompanzasyon için kullanılan D-STATCOM, 16,40 kVA (10kW+13kVAR) ve 22,36 kVA (10kW+20kVAR) gücünde iki ayrı test yükü kullanılmıştır. Bu yüklerin dağıtım hattında meydana getirdiği güç kalitesi problemleri modellenen D-STATCOM aracılığıyla giderilmeye çalışılmıştır. Yapılan benzetime göre, D-STATCOM şebekeye bağlandığında, sistemdeki gerilim dalgalanmasının ve toplam harmonik distorisyonunun (THD) büyük oranda azaldığı doğrulanmıştır. Sonuç olarak, D-STATCOM’un şebekedeki değişken yüklerin neden olduğu gerilim artışını veya çökmesini büyük ölçüde giderdiği, güç kaybını azalttığı ve buna bağlı olarak da gerilim kararlılığını arttırdığı gösterilmiştir.

Keywords:

Desing and Analysis Of D-statcom For Improving Power Quality In Micro Grids
2021
Journal:  
Politeknik Dergisi
Author:  
Abstract:

The current loads in industrial applications are based on inductive loads due to developing technology. The inductive loads consume inductive reactive energy owing to their electrical structures. The consumed reactive energy causes to decrements in power quality and efficiency of the system in addition to power factor deficiencies. The flexible alternating current transmission systems (FACTS) play an important role in improving the performance and quality of the power system. The control of power systems that are equipped with FACTS systems are accomplished more rapidly and easily comparing to regular compensations. The Distribution Static Synchronous Compensator (D-STATCOM) is the most common FACTS device used to increase power quality. D-STATCOM, also used for reactive power control, is a shunt connected device which is used to improve power quality in distribution systems. D-STATCOM exchanges reactive power with mains and prevents voltage fluctuations. In this study, a D-STATCOM that is based on voltage source converter and exchanges reactive power with the distribution line to eliminate power quality problems at the source has been modelled in MATLAB Simulink software and the simulation results were examined. In the modelled system, 4 km distribution line has been modelled with two separate test loads at 16.40kVA (10kW+13kVAR) and 22.36kVA (10kW+20kVAR) rated power, and the D-STATCOM model at the end of the line. The power quality problems caused by these loads on the distribution line were tried to be eliminated through the modelled D-STATCOM. According to the simulation results, it is confirmed that the voltage fluctuation and total harmonic distortion (THD) on the load side are remarkably reduced when the D-STATCOM is connected to the network. As the result, D-STATCOM has been shown to greatly overcome the voltage rise or sags caused by variable loads in the network, to reduce power loss and accordingly improve the voltage stability.