User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 23
 Downloands 2
COMPARATIVE ANALYSIS OF CASCADE REFRIGERATION SYSTEMS’ PERFORMANCE and ENVIROMENTAL IMPACTS
2019
Journal:  
Journal of the Turkish Chemical Society Section B: Chemical Engineering
Author:  
Abstract:

The aim of our study is to propose a theoretical model to analyze the energy efficient and environment friendly cascade system for various refrigerant pairs. In order to realize, the optimum cascade evaporation temperature (TOPT,CAS,E) which maximize the performance, COP values are determined for different refrigerant pairs of the system. After the optimization, two different cases have been investigated through a thermodynamic analysis to discover the best refrigerant pair for the system. Natural refrigerant CO2 is selected instead of R404A which has high Global Warming Potential (GWP) value for the low temperature cycle (LTC). On the other hand, synthetic refrigerants (R134a, R152a) and a natural refrigerant (NH3) are chosen for the high temperature cycle (HTC). In order to determine, an energy efficient and environmentally friendly cascade system, R134a/CO2, R152a/CO2 and NH3/CO2 refrigerant pairs are investigated in Case 1. On the other hand, R134a/R404A, R152a/R404A and NH3/R404A refrigerant pairs are investigated in Case 2. In calculations, the evaporation temperature (TE) is varied from -20oC to -40oC in LTC. The condensation temperature (TC) is considered to be between 30oC and 45oC in HTC. Mass flow rate requirements of systems for various refrigeration capacities (QEvap) are calculated for different refrigerant pairs. Moreover, the COPmax and total equivalent warming impact (TEWI) values of the system’s refrigerant pairs are evaluated and compared for various operating conditions.

Keywords:

0
2019
Author:  
Citation Owners
Information: There is no ciation to this publication.
Similar Articles








Journal of the Turkish Chemical Society Section B: Chemical Engineering

Field :   Mühendislik

Journal Type :   Ulusal

Metrics
Article : 104
Cite : 19
2023 Impact : 0.08
Journal of the Turkish Chemical Society Section B: Chemical Engineering