User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
  Citation Number 1
 Views 11
EXPERIMENTAL ASSESSMENT OF COMPARATIVE R290VS. R449A REFRIGERANTS BY USING 3E (ENERGY, EXERGY AND ENVIRONMENT) ANALYSIS: A SUPERMARKET APPLICATION
2021
Journal:  
Journal of Thermal Engineering
Author:  
Abstract:

Efficiency is becoming an increasingly important issue in cooling systems. It is important to use micro channel heat exchangers in order to increase the cooling system efficiency. In this study, performance analysis of refrigerants used in supermarkets was tested experimentally. Thermodynamic analyses of the refrigerants were examined. The compatibility of R290 and R449A refrigerants with the environment has been experimentally observed. Energy, exergy, and environmental analyses were performed using R290 and R449a refrigerants based on the test results for 24 hours using double inlet and double outlet evaporator. Accordingly, in the experiments using R290, the exergy efficiency and COP value are 43.52 % and 2.09, respectively. In experiments using R449A, these values were found to be 22.28 % and 1.59. Exergy efficiency was increased by 48.81 % in experiments using propane. In addition, an increase of 24.12% was observed in the Coefficient of Performance (COP) value. Considering the environmental analysis results, the amount of CO2 emitted by the R290 refrigerant to the atmosphere during the test period was 3.14 kg/h and R449A was calculated as 3.97 kg/h. It was seen in this study that the R290 refrigerant emits 26.22 % less CO2 to the atmosphere.

Keywords:

0
2021
Author:  
Citation Owners
Attention!
To view citations of publications, you must access Sobiad from a Member University Network. You can contact the Library and Documentation Department for our institution to become a member of Sobiad.
Off-Campus Access
If you are affiliated with a Sobiad Subscriber organization, you can use Login Panel for external access. You can easily sign up and log in with your corporate e-mail address.
Similar Articles










Journal of Thermal Engineering

Field :   Mühendislik

Journal Type :   Uluslararası

Metrics
Article : 493
Cite : 243
2023 Impact : 0.05
Journal of Thermal Engineering