Transformatörlerde Kazan Kayıplarının Azaltılmasında En Uygun Yatay Şönt Eleman Boyutu ve Konumunun Parametrik Sonlu Elemanlar Analizleri ile İncelenmesi
2019
Journal:  
Politeknik Dergisi
Author:  
Abstract:

Manyetik şönt kullanımı transformatörlerde meydana gelen kazan kayıplarının azaltılmasında etkin bir yöntemdir. Bu şönt elemanların kazan duvarlarının iç yüzeyine dikey olarak yerleştirilmesi, kazan kayıplarını önemli oranda azaltması sebebiyle transformatör üreticileri tarafından yaygın şekilde kullanılmaktadır. Bu çalışmada, şönt elemanların yatay biçimde kullanılması durumu değerlendirilmekte ve en uygun şönt eleman boyutu ve konumunun belirlenmesi hedeflenmektedir. Bu amaçla 1250kVA gücünde düşük kayıplı bir dağıtım transformatörü incelenmiştir. Öncelikle, transformatörde meydana gelen kazan kayıpları benzetim çalışmaları ile belirlenmiş ve deneysel ölçümler ile doğrulanmıştır. Ardından kazan kayıplarını etkin biçimde azaltmak için yatay şönt elemanların en uygun boyut ve konumunun belirlenmesi amacıyla parametrik analizler gerçekleştirilmiştir. Elde edilen sonuçlar, göz önünde tutulan diğer kriterlere de bağlı olarak kazan kayıplarının yaklaşık %80 oranında azaltılabildiğini göstermektedir.

Keywords:

Investigation Of The Optimal Dimension and Location Of Horizontal Shunts In Transformers With Parametrical Finite Element Analyses
2019
Journal:  
Politeknik Dergisi
Author:  
Abstract:

Magnetic shunting is an efficient way to reduce stray losses in transformer tank walls. Due to the vertical placement of these shunts inside the tank walls are greatly reduce these losses, this method are widely used by transformer manufacturers. In this study, authors are focused on horizontal shunting method and optimal dimensions and locations of these shunts are investigated. A 1250kVA high efficient distribution transformer is studied. First, stray losses on tank walls were calculated by simulations and obtained results were verified by measurements. Then, a number of analyses were conducted parametrically to obtain the optimal position and dimensions of the horizontal shunts. Analysis results show that, considering the other important issues such as cooling efficiency of tank walls, stray losses on tank walls are reduced by 80%.

Keywords: