User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 ASOS INDEKS
 Views 5
 Downloands 1
Comparative Optical and Thermal Analysis of Compound Parabolic Solar Collector with Fixed and Variable Concentration Ratio
2022
Journal:  
Engineering Proceedings
Author:  
Abstract:

: Solar thermal collectors, such as flat plate and evacuated tube collectors, are used for maximum of 60–80 °C temperature and parabolic trough collectors are used for 700–900 °C temperature ranges. It is needed to develop and analyze solar collectors, such as compound parabolic collectors (CPC) which can operate in an intermediate temperature range from 50–300 °C for industrial and domestic applications. However, optical and thermal performance of CPC is strongly influenced by concentration ratio. The current study presents a comparative optical and thermal analysis of CPC with fixed (4) and variable (4.5 to 5.7) concentration ratio by using model-based transient simulation approach. Two profiles of compound parabolic collector are analyzed with fixed and variable concentration ratio for the subtropical climate of Taxila, Pakistan. 2D profiles of both collectors are modeled and designed in MATLAB and are then analyzed optically by using Monte Carlo ray tracing technique through TracePro. In addition, thermal analysis of both profiles is also performed through ANSYS. The resulting optical efficiencies with fixed and variable concentration are 72% and 79%, respectively. Whereas maximum temperature achieved with both profiles is 352 K and 367 K, respectively. Thus, it is concluded that performance of CPC with variable concentration ratio is much better compared to fixed value.

Keywords:

0
2022
Author:  
Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles








Engineering Proceedings

Journal Type :   Uluslararası

Engineering Proceedings