User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 7
Duzeltme: Yogun Bakimda Uygulanan Endotrakeal Aspirasyon İslem Basamaklarinin Aspirasyon Komplikasyonlarina Etkisi
2024
Journal:  
Adnan Menderes Üniversitesi Sağlık Bilimleri Fakültesi Dergisi
Author:  
Abstract:

Amaç: Rehber önerileri doğrultusunda yapılmayan aspirasyon işlemleri komplikasyonlara yol açmaktadır. Çalışmanın amacı, aspirasyon standardı uygulanmayan bir yoğun bakım ünitesinde aspirasyon işlem basamaklarında sıklıkla yapılan hataları belirlemek ve aspirasyon komplikasyonlarını incelemektir. Yöntem: Çalışma üçüncü basamak bir yoğun bakım ünitesinde gözlemsel desende yürütülmüştür. Hemşirelerin aspirasyon sırasındaki işlem basamakları gözlenmiş; hastaların aspirasyondan hemen önce ve sonrasındaki birinci ve beşinci dakikalarda kan basıncı, kalp atım hızı, solunum sayısı, periferal oksijen satürasyonu, tidal volüm değerleri, aritmi, hemorajik sekresyon gelişimi takip edilmiştir. Bulgular: Toplam 35 hemşirenin 45 hastada uyguladığı 210 aspirasyon işlemi izlenmiştir. Hemşirelerin en sık yaptığı uygulama hataları 150 mmHg üstü aspiratör basıncını (%99.5) 10 sn’den fazla uygulama (%63.3), aspirasyon öncesi ve sonrası hiperoksijenasyon uygulamama (%98.1, %96.2), derin aspirasyon uygulama (%97.6), aspirasyonun toplam süresinin 15 sn’den fazla sürmesi (%72.9) olarak belirlenmiştir. On saniyeden fazla aspiratör basıncı uygulamak birinci dakikada taşikardi görülme riskini 3.074, hemorajik sekresyon riskini 2.790, takipne riskini 2.024, desatürasyon riskini 5.496 kat arttırmıştır. Toplam aspirasyon süresini 15 sn’den fazla uygulamak birinci dakikada diyastolik hipotansiyon riskini 15.108, aritmi riskini 2.630, beşinci dakikada taşikardi görülme riskini 3.725, takipne riskini 2.750 kat arttırmıştır. Sonuç: Bu çalışmanın sonuçları, hemşirelerin aspirasyon standardına uygun olmayan birçok hatalı işlem yaptığını, hatalı yapılan her işlemin hastalarda önemli fizyolojik değişimlere yol açtığını göstermektedir.  

Keywords:

Duzeltme: Effects Of Endotracheal Suctioning Procedure Steps Applied In Intensive Care On Suctioning Complications
2024
Author:  
Abstract:

Objective: Suctioning procedures that are not carried out under guidelines lead to complications. The aim of the study is to determine suctioning procedure mistakes and complications related the procedure in an intensive care unit (ICU) where no standard suctioning guidelines were applied. Methods: The study was used an observational research design in a tertiary ICU. The procedure steps of nurses during suctioning were observed; blood pressure, heart rate, respiratory rate, peripheral oxygen saturation, tidal volume values, development of arrhythmia and hemorrhagic secretion were monitored in patients just before and at the first and the fifth minutes after suctioning. Results: A total of 210 suctioning procedures performed by 35 nurses on 45 patients were observed. Nurses’ frequent mistakes were applying suction pressure above 150 mmHg (99.5%) for more than 10 seconds (63.3%), not applying hyperoxygenation before and after suctioning (98.1%, 96.2), applying deep suctioning (97.6%), applying total suctioning procedure for more than 15 seconds (72.9%). Applying suctioning pressure for more than 10 seconds increased the risk of tachycardia by 3.074 times, hemorrhagic secretion risk by 2.790 times, tachypnea risk by 2.024 times, and desaturation risk by 5.496 times in the first minute. Applying suctioning pressure for more than 15 seconds increased the risk of diastolic hypotension by 15.108 times, the arrhythmia by 2.630 times in the first minute; tachycardia by 3.725 times, tachypnea by 2.750 times in the fifth minute. Conclusion: Many incorrect procedures applied by nurses, which did not comply with the suctioning standards, led to significant physiological changes in patients.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles












Adnan Menderes Üniversitesi Sağlık Bilimleri Fakültesi Dergisi

Field :   Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 269
Cite : 663
© 2015-2024 Sobiad Citation Index