User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 12
 Downloands 2
Evsel Nitelikli Gri Suyun Geri Kazanılabilirliğinin Araştırılması
2023
Journal:  
Aksaray University Journal of Science and Engineering
Author:  
Abstract:

Su kaynaklarının azalması sonucu artan su gereksinimlerini sağlamak için gri suların arıtılması ve yeniden kullanılması amaçlanmaktadır. İçme sularını korumak hedefiyle gri suların arıtılarak geri kazanılması alternatif bir kaynak oluşturmaktadır. Duşlardan, banyo ve mutfak lavabolarından, çamaşır ve bulaşık makinelerinden gelen gri sular evsel atık suyun büyük bir kısmını oluşturmaktadır. Gri su toplam kirletici yükünü düşük miktarda içermektedir. Tuvalet harici atık suları içeren gri sular toplam evsel su kullanımının %55-80’lik kısmını oluşturmaktadır. Bu çalışmada kullanılan gri su, Kocaeli İl’i İzmit İlçesi’nde 6 daireden oluşan 20-24 kişilik konuttan temin edilmiştir. Çeşitli gri su geri dönüşüm arıtma teknolojileri arasında AKR (Ardışık Kesikli Reaktör), gri sudan çözünmüş askıda katı madde ve nutrient gideriminin azaltılmasında etkili bir arıtma tekniğidir. Gri suyu arıtmak için laboratuar ölçekli bir AKR, pilot tesis olarak tasarlanmıştır. 1 günlük ve 2.5 günlük hidrolik reaksiyon sürelerinde(HRT) su örnekleri toplanmıştır. HRT 1 günde elde edilen sonuçlarda ort. pH değeri 7.32, ort. E.İ. değeri 586.8 µS/cm, ort. Ç.O. değeri 3.30 mg/L, ort. bulanıklık değeri 7.39 NTU ve ort. bulanıklık giderim verimi %99, ort. AKM değeri 6.92 mg/L ve ort. AKM giderim verimi %98, ort. fosfor değeri 7.51 mg/L ve ort. fosfor giderim verimi %84, ort. azot değeri 15.92 mg/L ve ort. azot giderim verimi %59 ve ort. KOİ değeri 569 mg/L ve ort. giderim verimi %69 olarak ölçülmüştür. HRT 2.5 günde elde edilen sonuçlarda ort. pH değeri 7.76, ort. E.İ. değeri 574.6 µS/cm, ort. Ç.O. değeri 5.07 mg/L, ort. bulanıklık değeri 4.34 NTU ve ort. bulanıklık giderim verimi %99, ort. AKM değeri 4.72 mg/L ve ort. AKM giderim verimi %98, ort. fosfor değeri 3.79 mg/L ve ort. fosfor giderim verimi %89, ort. azot değeri 13.02 mg/L ve ort. azot giderim verimi %54 ve ort. KOİ değeri 368 mg/L ve ort. giderim verimi %70 olarak ölçülmüştür.

Keywords:

Investigation Of Recyclability Of Domestic Gray Water
2023
Author:  
Abstract:

It is aimed to treat and reuse gray water in order to meet the increased water requirements as a result of the decrease in water resources. Purifying and recycling gray water with the aim of protecting drinking water is an alternative resource. Gray water from showers, bathroom and kitchen sinks, washing machines and dishwashers constitute a large part of domestic wastewater. Gray water contains a low amount of total pollutant load. Gray waters, which include waste water other than toilets, constitute 55-80% of the total domestic water use. The gray water used in this study was obtained from a residence of 20-24 people consisting of 6 flats in Kocaeli province, Izmit district. Among the various gray water recycling treatment technologies, SBR (Sequential Batch Reactor) is an effective treatment technique for reducing dissolved suspended solids and nutrient removal from gray water. A lab-scale SBR was designed as a pilot plant to treat gray water. Water samples were collected at 1-day and 2.5-day hydraulic reaction times (HRT). In the results obtained in 1 day of HRT; avg. pH value 7.32, avg. EC value 586.8 µS/cm, avg. DO value 3.30 mg/L, avg. turbidity value of 7.39 NTU and avg. turbidity removal efficiency 99%, avg. TSS value of 6.92 mg/L and avg. TSS removal efficiency 98%, avg. phosphorus value is 7.51 mg/L and avg. phosphorus removal efficiency 84%, avg. nitrogen value is 15.92 mg/L and avg. nitrogen removal efficiency 59% and avg. COD value is 569 mg/L and avg. removal efficiency was measured as 69%. In the results obtained in 2.5 days of HRT; avg. pH value 7.76, avg. EC value 574.6 µS/cm, avg. DO value 5.07 mg/L, avg. turbidity value of 4.34 NTU and avg. turbidity removal efficiency 99%, avg. TSS value of 4.72 mg/L and avg. TSS removal efficiency 98%, avg. phosphorus value is 3.79 mg/L and avg. phosphorus removal efficiency 89%, avg. nitrogen value 13.02 mg/L and avg. nitrogen removal efficiency 54% and avg. COD value is 368 mg/L and avg. the removal efficiency was measured as 70%.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles










Aksaray University Journal of Science and Engineering

Field :   Fen Bilimleri ve Matematik; Mühendislik

Journal Type :   Ulusal

Metrics
Article : 81
Cite : 61
Aksaray University Journal of Science and Engineering