User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 12
 Downloands 2
Analytical Method Development and Validation for Simultaneous Determination of Simvastatin and Mupirocin Using Reverse-Phase High-pressure Liquid Chromatographic Method
2021
Journal:  
The Turkish Journal of Pharmaceutical Sciences
Author:  
Abstract:

Objectives: This study was aimed to develop and validate the use of reverse-phase high pressure liquid chromatographic method for the estimation of simvastatin (SIM) and mupirocin (MUP) simultaneously. Materials and Methods: The chromatographic method developed is optimized for flow rate with the column, solvent, and buffer used and mobile phase ratio, molarity, and pH. The validation of the optimized method and the forced degradation studies of both drugs (under acidic, alkaline, oxidation, heat, light, and neutral conditions) were conducted following the The International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use guidelines. Results: Kromasil C18 column (250 mm × 4.6 mm, 5 µm) with ultraviolet detection at 224 nm and acetonitrile/phosphate buffer (30 mM, 70:30 v/v, pH 3.5; adjustment done using orthophosphoric acid) as mobile phase at a flow rate of 1.1 mL/min were observed to provide a good resolution for MUP and SIM at retention times of 2.32±0.008 and 13.55±0.254 min, respectively, with high accuracy (percent recovery was 99.69±0.82 for MUP and 101.10±0.02 for SIM) and linearity in the range of 5-30 µg/mL (r2: 0.9969 for MUP and r2: 0.9959 for SIM). The diagnostic limit and the lower limit of determination were 0.771±0.234 and 2.338±0.246 μg/mL for MUP and 0.595±0.282 and 1.803±0.334 µg/mL for SIM, respectively. The validated method was used to understand the degradation behavior of both drugs after the forced degradation studies. Conclusion: The analytical method developed is determined to be specific, sensitive, precise, and accurate for the estimation of MUP and SIM simultaneously in the combined dosage form.

Keywords:

2021
Author:  
0
2021
Author:  
Citation Owners
Information: There is no ciation to this publication.
Similar Articles










The Turkish Journal of Pharmaceutical Sciences

Field :   Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 226
Cite : 48
2023 Impact : 0.051
The Turkish Journal of Pharmaceutical Sciences