User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 9
Behavior of Base-Isolated Liquid Storage Tanks with Viscous Dampers under Historical Earthquakes Considering Superstructure Flexibility
2024
Journal:  
Turkish Journal of Civil Engineering
Author:  
Abstract:

Liquid storage tanks (LSTs) can be efficiently protected from far-fault earthquakes by base-isolation. However, large isolation system and sloshing displacements may threaten the tank’s safety under near-fault earthquakes. Although the application of supplemental viscous dampers (VDs) at the base-isolation systems of LSTs located in near-fault areas may help, it may also increase superstructure demands under far-fault earthquakes. In addition to the characteristics of the earthquake, the isolation system and the superstructure properties may affect the success of base-isolated LSTs with supplemental VDs. Therefore, a numerical investigation is conducted in this study in order to determine the influence of the supplemental viscous damping ratio, the isolation system period, the tank wall flexibility, and the tank slenderness ratio on the seismic responses of base-isolated cylindrical steel LSTs with supplemental VDs including the base displacement, the sloshing displacement, and the normalized isolation system shear force under both near-fault and far-fault historical earthquake records. The tank is modeled by single-degree-of-freedom systems representing different modes on a common isolation basemat and the nonlinear dynamic analyses are carried out in 3D-BASIS-ME software. Findings show that while supplemental damping is required especially when LSTs with long-period isolation systems are subjected to large magnitude near-fault earthquakes, it may also cause amplifications in the sloshing displacement and isolation system shear force demands in case of far-fault earthquakes. Furthermore, it is determined that the influence of tank flexibility on both the superstructure and the isolation system responses is negligibly small while the tank slenderness ratio may have considerable effects.

Keywords:

0
2024
Author:  
Citation Owners
Information: There is no ciation to this publication.
Similar Articles










Turkish Journal of Civil Engineering

Journal Type :   Uluslararası

Metrics
Article : 608
Cite : 1.926
Turkish Journal of Civil Engineering