User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 2
Indirect Determination of Diclofenac Sodium Through its Interaction with the Aniline Oxidation Peak
2024
Journal:  
Journal of the Turkish Chemical Society Section A: Chemistry
Author:  
Abstract:

The voltammetric measurement of diclofenac sodium was investigated using an electrochemical sensor consisting of a glassy carbon electrode (GCE) modified with aniline conducting polymer and a differential pulse voltammetric (DPV) method. Diclofenac sodium behavior was investigated through its interaction with poly aniline oxidation peak; due to diclofenac sodium adsorption on the surface of the bare glassy carbon electrode, it gives an unstable oxidation peak at 0.4V versus Ag/AgCl.saturated.KCl. We attempted to solve this issue by plating the electrode with aniline and monitoring the interaction peak between diclofenac sodium and aniline oxidation peak. The impact of pH was investigated, optimum conditions were tested, and calibration curves were constructed. Glassy carbon/poly aniline electrode (GC/PAn) results in two straight lines with R2 values of 0.9812 and 0.9772 when current is plotted against concentrations at low concentration and high concentration, respectively. The limit of detection (LOD) and limit of quantification (LOQ) were 0.1282 × 10-7 M and 0.4275 × 10-7 M, respectively. Compared with other sensors, it was observed that the proposed electrochemical sensor has a wider linear range and lower detection limit. The suggested method was applied successfully for quantitating diclofenac sodium in tablet formulation supplied by Samaraa Drugs Industry (SDI)with accepted results of recovery of diclofenac sodium.

Keywords:

0
2024
Author:  
Citation Owners
Information: There is no ciation to this publication.
Similar Articles








Journal of the Turkish Chemical Society Section A: Chemistry

Field :   Fen Bilimleri ve Matematik

Journal Type :   Ulusal

Metrics
Article : 843
Cite : 321
Journal of the Turkish Chemical Society Section A: Chemistry