Kalsiyum Hidroksit İçerikli Medikamentlerin Radyopasite Miktarının Görüntü Analizi ile Belirlenmesi
2022
Journal:  
Ege Üniversitesi Dişhekimliği Fakültesi Dergisi
Author:  
Abstract:

GİRİŞ ve AMAÇ: Bu makalenin amacı, kalsiyum hidroksit içerikli kanal içi medikamentlerin radyoopasitesini güncel görüntü analiz yöntemleriyle karşılaştırmaktır. YÖNTEM ve GEREÇLER: Bu çalışmada üç farklı ticari kalsiyum hidroksit medikamenti kullanıldı. Radyografik görüntü verileri Uluslararası Standardizasyon Örgütü #6876: 2012 yönergelerine göre elde edildi. Her bir numune için analiz edilecek bölge belirlendi. X-ışını görüntü verilerinin ortalama (± SD) gri değerleri bir görüntü analiz yazılımı ile ölçüldü. Numunelerin ortalama gri değerleri ile step-wedge için belirlenen gri değerler bir kalibrasyon eğrisi oluşturularak mmAl değerlerine dönüştürüldü. Veriler tek yönlü varyans analizi ve ardından Tukey’in çoklu karşılaştırma testi ile analiz edildi. BULGULAR: Tüm medikamentlerin ortalama radyoopasite değerlerinde anlamlı farklılık oluştu (p<0,05). Ortalama radyoopasite değerleri şu şekilde sıralandı: TempCanal (4,94±0,31mmAl) > ProCalR (2,63±0,05mmAl) > Kontrol (2,19±0,11mmAl). TARTIŞMA ve SONUÇ: Radyoopak kalsiyum hidroksit içerikli medikamentlerin radyoopasite değerleri arasında yüksek farklılık ortaya çıkmıştır. Medikamentler 2,19 ila 4,94 mm alüminyum eşdeğerinde radyoopasite göstermiş olmasına rağmen, yalnızca TempCanal uluslararası standart olan 3 mm alüminyum eşdeğerinin üzerinde değerler kaydetmiştir.

Keywords:

Determination of the amount of radiopathy of calcium hydroxide-containing medications by image analysis
2022
Author:  
Abstract:

Introduction and Purpose: The purpose of this article is to compare the radioopathy of in-channel medications containing calcium hydroxide with current image analysis methods. Method and Requirements: In this study, three different commercial calcium hydroxide medications were used. Radiographic image data was obtained according to the International Organization for Standardization #6876: 2012 guidelines. The area to be analyzed for each sample was determined. The average (± SD) grey values of X-ray image data were measured by an image analysis software. The average grey values of samples and the grey values specified for step-wedge were converted into mmAl values by creating a calibration curve. The data was analyzed by one-way variance analysis and then by Tukey's multi-comparative test. A significant difference was made in the average radiopathy values of all medications (p<0,05). The average radioopasity values are classified as follows: TempCanal (4,94±0,31mmAl) > ProCalR (2,63±0,05mmAl) > Control (2,19±0,11mmAl). RELATED AND RESULTATED: There is a high difference between the radioopacity values of drugs containing calcium hydroxide. Although the medications showed radiopathy in the aluminum equivalent of 2.19 to 4.94 mm, only TempCanal recorded values above the aluminum equivalent of 3 mm, which is the international standard.

Keywords:

Citation Owners
Information: There is no ciation to this publication.